@InProceedings{SouzaFroMatOliMor:2017:DeCoCo,
               author = "Souza, Greison Moreira de and Fronza, Jos{\'e} Guilherme and 
                         Mataveli, Guilherme Augusto Verola and Oliveira, Bruno Silva and 
                         Moraes, Elisabete Caria",
          affiliation = "{Instituto Nacional de Pesquisas Espaciais (INPE)} and {} and {} 
                         and {Instituto Nacional de Pesquisas Espaciais (INPE)} and 
                         {Instituto Nacional de Pesquisas Espaciais (INPE)}",
                title = "Determina{\c{c}}{\~a}o do coeficiente de combust{\~a}o e do 
                         fator de combust{\~a}o da vegeta{\c{c}}{\~a}o da fitofisionomia 
                         do cerrado campo limpo com o uso da Energia Radiativa do Fogo",
            booktitle = "Anais...",
                 year = "2017",
               editor = "Gherardi, Douglas Francisco Marcolino and Arag{\~a}o, Luiz 
                         Eduardo Oliveira e Cruz de",
                pages = "493--500",
         organization = "Simp{\'o}sio Brasileiro de Sensoriamento Remoto, 18. (SBSR)",
            publisher = "Instituto Nacional de Pesquisas Espaciais (INPE)",
              address = "S{\~a}o Jos{\'e} dos Campos",
             abstract = "The aim of this study was to determine the combustion coefficient 
                         and combustion factor from a combustion laboratory experiment 
                         conducted with plant species collected in physiognomy of clean 
                         field of savanna biome in Sempre-Vivas National Park (PNSV). The 
                         plant material was exposed to the combustion process with samples 
                         different weights of 0.025; 0.1; 0.15; 0.2; 0.25 and 0.5 kg at 7 
                         samples for each biomass weight, counting the total of 42 
                         measurements. After combustion of each sample of biomass that was 
                         not consumed, was collected for weighing. A thermal camera was 
                         used (FLIR A310) to measure the temperature of burning. After the 
                         experiment, in possession of the data collected by the thermal 
                         camera, they were processed for the Radiative Fire Power (FRP, 
                         MJ.s-1) and the radiative energy Fire (ERF, MJ). The combustion 
                         coefficient was 0.8263 kg.MJ-1, this value means that each 0.8263 
                         kg of biomass burning in area under study, 1 MJ is released. In 
                         the experiment 85.5% of the biomass was consumed after the passage 
                         of fire, this value represents the factor of combustion.",
  conference-location = "Santos",
      conference-year = "28-31 maio 2017",
                 isbn = "978-85-17-00088-1",
                label = "59496",
             language = "pt",
         organisation = "Instituto Nacional de Pesquisas Espaciais (INPE)",
                  ibi = "8JMKD3MGP6W34M/3PS44D7",
                  url = "http://urlib.net/ibi/8JMKD3MGP6W34M/3PS44D7",
           targetfile = "59496.pdf",
                 type = "Floresta e outros tipos de vegeta{\c{c}}{\~a}o",
        urlaccessdate = "27 abr. 2024"
}